Caspian Journal of Internal Medicine، جلد ۱۲، شماره ۴، صفحات ۵۷۳-۵۷۹

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Accuracy of mammography and ultrasonography and their BI-RADS in detection of the breast malignancies
چکیده انگلیسی مقاله Background: We aimed to compare the diagnostic accuracy of mammography and ultrasonography and their breast imaging-reporting and data system (BI-RADS) classification versus breast core needle biopsy (CNB) findings in distinguishing the breast masses. Methods: This cross-sectional study was conducted during 2016-2018 on female patients who were referred to a radiology center in Babol, northern Iran, for routine screening and/or for CNB. Patients underwent sonography and mammography by a senior radiologist. The breast lesions were also evaluated according to BI-RADS classification. CNB was performed on the breast masses by the same radiologist and pathological procedures were performed by an expert pathologist. Descriptive statistics were used to analyze the data. Results: In total, 213 breast masses were finally assessed, of which 107 (50.2 %) masses were benign and 106 (49.8 %) masses were malignant. The sensitivity for mammography and ultrasound alone was 72.6% and 68.9%, respectively. This rate for combined mammography and ultrasound was 84.9%. About BI-RADS classification, 28 masses were classified as BI-RADS 3, 99 as BI-RADS 4A, 4 as BI-RADS 4B, 18 as BI-RADS 4C, and 64 as BI-RADS 5. BI-RADS 4A had the highest sensitivity (70.1%) among BI-RADS categories. The highest specificity pertained to BI-RADS 3 and 5 (100%) among BI-RADS categories. Also, the highest accuracy was related to BI-RADS 5 (80.3%). Conclusion: The results of the present study showed that combined mammography and ultrasound had a higher rate of accuracy than mammography or ultrasound alone. Furthermore, the imaging methods BI-RADS classification had an acceptable positive predictive value.
کلیدواژه‌های انگلیسی مقاله Ultrasonography, mammography, core needle biopsy, breast malignancy

نویسندگان مقاله | Naser Ghaemian
Department of Radiology, Shahid Beheshti Hospital, Babol University of Medical Sciences, Babol, Iran


| Neda Haji Ghazi Tehrani
Student Research Committee, Babol University of Medical Sciences, Babol, Iran


| Mehrdad Nabahati
Department of Radiology, Shahid Beheshti Hospital, Babol University of Medical Sciences, Babol, Iran



نشانی اینترنتی http://caspjim.com/browse.php?a_code=A-10-2130-1&slc_lang=en&sid=1
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده Radiology
نوع مقاله منتشر شده Original Article
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات